Service & Maintenance
Emergency repair and scheduled preventative maintenance for commercial, industrial and residential doors.
Door down? Call dispatch.
A shipping door stuck open, a parkade gate down or a door that won't close affects your whole building. Call dispatch to get a crew moving, then send the details so the work order has everything.
(289) 828-0075- Broken springs & cables
- Doors off track or jammed
- Damaged high-speed curtains
- Failed operators & controls
- Parkade gate faults
- Worn rollers & hinges
- Damaged bottom & perimeter seals
- Impact-damaged sections
Scheduled service, written records, fewer emergency calls
A structured PM program for portfolios and single sites. Every visit produces a written compliance report for your building insurance records, and every deficiency comes with a priority and a quote.
Walk every opening and record type, size, operator and condition.
Each door tagged and logged with photos and spring ratings.
Frequency set by traffic, environment and life-safety role.
Multi-point inspection with counterbalance and cable work.
Written audit report with prioritized deficiencies.
Annual Compliance
Low-traffic doors and annual safety checks.
- 16-point door inspection
- Counterbalance recalibration
- Cable safety tensioning
- Safety device & reversing tests
- Written compliance report
- Dedicated emergency window
Semi-Annual
Mixed fleets, plazas and manufacturing sites.
- Everything in Tier 1, twice yearly
- Operator & access control check
- Spring cycle-life tracking
- Asset register with photo log
- Dedicated emergency window
Quarterly High-Cycle
Parkades, high-speed doors and busy shipping doors.
- Everything in Tier 2, quarterly
- VFD fault log review
- Loop and light curtain calibration
- Annual portfolio summary report
- Dedicated emergency window
- 01Torsion springs & cycle wear
- 02Lift cables & terminations
- 03Cable drums
- 04Shaft, bearings & couplers
- 05Track alignment & mounting
- 06Rollers, hinges & fasteners
- 07Sections, slats or curtain
- 08Perimeter & bottom seals
- 09Operator, limits & brake
- 10VFD settings & fault log
- 11Control stations & wiring
- 12Manual release & hoist
- 13Reversing edge
- 14Photo-eyes & light curtains
- 15Loop detectors
- 16Emergency release & manual operation
| Asset | Finding | Priority |
|---|---|---|
| P1-ENT | Lift cable fraying at east drum. Door tagged out of service. | Replace 7 days |
| P1-ENT | Spring cycle count est. 252,600 of 300,000. Budget replacement. | Next quarter |
| FD-03 | Rolling door closing slow. Spring tension adjusted, recheck due. | Retest 30 days |
| SD-07 | Photo-eyes and reversing edge tested. Bottom seal within wear limit. | Pass |